Tiny Motor Dynamometer Test System
Micro Motor Dynamometer Test System
It adopts the unique Prony (winding) braking technology, which is mainly used for the characteristic test of micro-motors.
Torque range: 0.1mNm~400mNm.
Speed up to 60,000rpm
It adopts the unique Prony (winding) braking technology, which is mainly used for the characteristic test of micro-motors.
Torque range: 0.1mNm~400mNm.
Speed up to 60,000rpm
Tiny Motor Dynamometer Test System
Load-Sensor & Pulley Specifications:
Model | Load Sensor | Pulley Radius (mm) | ||||
---|---|---|---|---|---|---|
Directly wound on the shaft *1 |
2.5mm | 5mm | 10mm | 20mm | ||
JP-R5N | 0.5N | - | 1.25mNm | 2.5mNm | 5mNm | 10mNm |
JP-1N | 1N | - | 2.5mNm | 5mNm | 10mNm | 20mNm |
JP-2N | 2N | - | 5mNm | 10mNm | 20mNm | 40mNm |
JP-5N | 5N | - | 12.5mNm | 25mNm | 50mNm | 100mNm |
JP-10N | 10N | - | 25mNm | 50mNm | 100mNm | 200mNm |
JP-20N | 20N | - | 50mNm | 100mNm | 200mNm | 400mNm |
Torque = Load-Sensor Rating(N) × Pulley Radius(mm)
*1: Torque will be related to motor shaft Radius.
*1: Torque will be related to motor shaft Radius.
Profile:
Adopting the unique Prony (winding) braking technology,
It is available to measure high-precision T-N curve
Advantages:
- No inertia & No coupling loss:
Due to using the Prony method, there are no inertial forces and coupling losses during the test. They are crucial that affecting the accuracy of the testing of micro motors. - Wide Measuring Range:
Six modes of the sensor, to select the proper sensor and pulley
The measuring Range is from 0.1 to 400 mNm. - Monitoring and analysis easier:
Real-time display of the testing results on the screen.
Data-File can be exported to Excel format. - High Speed:
The Max. Speed up to 60,000rpm - Add a power analyzer and you can measure V/A/W and the efficiency of the motor.
Measured Example:
(X-axis:Speed / Y-axis:Torque)
Specifications:
Brake | Prony braking |
---|---|
Load-Sensor | Six types:0.5N, 1N, 2N, 5N, 10N, 20N |
Sensor sensitivity | DC 2 V/ rating |
Torque precision | Within ± 1% of torque range |
Maximum allowable load | 200% of Sensor rating |
Torque meas. range | T=Sensor Rating X Pulley Diameter/ 2 |
Operating System | Microsoft Windows |
Power supply | Single-phase AC100-120V ± 10%,50/ 60 Hz |
Single-phase AC200-240V ± 10%,50/ 60 Hz |